Инструкция по эксплуатации PB Heat - WV Series, WBV Series

background image

WBV/WV

Boilers

Series

Oil

I n s t a l l a t i o n ,
O p e r a t i o n &
M a i n t e n a n c e
M a n u a l

As an

E

NERGY

S

TAR

®

Partner, PB Heat, LLC has determined that certain firing

rates of this product meet the

E

NERGY

S

TAR

®

guidelines for energy efficiency.

Страницы:
Скачать Пожаловаться

Краткое содержание руководства

  • p. 1/26
    WBV/WV Boilers Series Oil I n s t a l l a t i o n ,O p e r a t i o n &M a i n t e n a n c eM a n u a l As an E NERGY S TAR ® Partner, PB Heat, LLC has determined that certain firing rates of this product meet the E NERGY S TAR ® guidelines for energy
  • p. 2/26
    USING THIS MANUAL 1 A. INSTALLATION CLEARANCE . . . . . . . . . . . . .1 B. SPECIAL ATTENTION BOXES . . . . . . . . . . . .1 1. PREINSTALLATION 2 A. CLEARANCES . . . . . . . . . . . . . . . . . . . . . . . .2 B. AIR FOR COMBUSTION AND VENTILATION . . . .
  • p. 3/26
    1 A. INSTALLATION CLEARANCE Follow the installation instructions provided in thismanual in the order shown. The order of theseinstructions has been set in order to provide the installerwith a logical sequence of steps that will minimizepotential interferences
  • p. 4/26
    2 A. CLEARANCES Unit may be installed on combustible flooring, provided theboiler is not set on carpet and a metal drip pan is placedunder the appliance. Unit may be installed in a closet with the above clearances.See also Section B, Air for Combustion and
  • p. 5/26
    3 C. CHIMNEY / VENT AND DRAFT CONTROL 1. Draft Requirement – Minimum draft required in the vent system is -.03" to -.06" W.C. depending onboiler model, see Table 7.1 (Section 7). This draft isnecessary to provide the necessary draft over fire of
  • p. 6/26
    4 A. SETTING THE BOILER 1. Provide a level foundation, located as close as possible to the center of the heating system. 2. Refer to Figures 2.1 and 2.2 for exploded view of boiler while checking and/or assembling parts of theboiler. 3. On packaged boilers,
  • p. 7/26
    BOILER PLACEMENT AND ASSEMBLY (See Table 8.1 for parts identification). Figure 2.1: Steam boiler 5 Figure 2.2: Water boiler
  • p. 8/26
    A. PRESSURE TEST BLOCK ASSEMBLY 1. Make up cold water supply connection to the boiler. 2. Install pressure gauge or pressure-temperature gauge in tapping provided. See Boiler Dimensionaldrawing, Figures 7.1 and 7.2 (Section 7) 3. Plug all open tappings in
  • p. 9/26
    7 E. TANKLESS HEATER OR COVERPLATE 1. If a tankless coil is used (item 9), install as pictured. On water boilers, install in opening in front section.On steam boilers, install in opening in rear section.For suggested piping of tankless water heaters referto
  • p. 10/26
    8 Figure 3.6: Piping with Peerless Indirect Water Tank Figure 3.7: Float Low Water Cut-off PIPING AND CONTROLS Figure 3.5: Piping to Isolate Boiler from Chilled Medium on Chiller Systems
  • p. 11/26
    9 A. GENERAL All electrical wiring shall be done in accordance with theNational Electrical Code and Local Requirements. Singlepole switches including those of safety controls orprotective devices shall not be wired in a grounded line. B. BURNER WIRING 1.
  • p. 12/26
    10 ELECTRICAL Figure 4.3: Water Boilers, Packaged Figure 4.2: Water Boilers, Knockdown
  • p. 13/26
    11 ELECTRICAL Figure 4.5: Steam with Probe Low Water Cut-off Figure 4.4: Steam with Float Low Water Cut-Off
  • p. 14/26
    12 ELECTRICAL Figure 4.6: Zoning with Circulators Figure 4.7: Zoning with Zone Valves
  • p. 15/26
    13 BURNER SETUP & BOILER OPERATION A. BURNER INSTALLATION 1. The oil burner is supplied with a mounting flange fixed in position. 2. Mount the burner to the burner mounting plate (item 5) with four (4) 5/16" studs and nuts provided. 3. Care must
  • p. 16/26
    14 BURNER SETUP & BOILER OPERATION E. CLEAN THE BOILER (STEAM BOILERS ONLY) 1. Clean the boiler within one week after initial start-up. Cleaning will be more effective if boiler operates aday or two to loosen sediment and impurities insystem. 2. Boiler
  • p. 17/26
    15 BURNER SETUP & BOILER OPERATION BECKETT BURNER SPECIFICATIONS Boiler Model No. Burner Model No. Burner Head Static Plate Nozzle Size Pump Pressure Start-up Settings Head Setting Air Shutter Air Band WBV-03-085 AFG-F3¹ F3 3-3/8" 0.75 80° B HAGO³
  • p. 18/26
    16 MAINTENANCE 6. MAINTENANCE WARNING Product Safety Information Refractory Ceramic Fiber Product This appliance contains materials made from refractory ceramic fibers (RCF). Airborne RCF,when inhaled, have been classified by the International Agency for
  • p. 19/26
    17 MAINTENANCE A. GENERAL 1. Check pipes adjacent to cold walls or in unheated spaces. Insulate and tape them if necessary to besure they can't freeze up. Keeping the water movingat all times will reduce the likelihood of freezing. 2. If there is considerable
  • p. 20/26
    18 MAINTENANCE 2. To thoroughly clean the boiler it must be brushed down from the top. Alternatively, for limited space orminimum clearance to combustible installations,cleaning the heat exchanger from the combustionchamber side is acceptable. If unit is
  • p. 21/26
    19 BOILER DIMENSIONS & RATINGS 7. BOILER DIMENSIONS & RATINGS Figure 7.1: Boiler Dimensions, Water Boiler Figure 7.2: Boiler Dimensions, Steam Boiler BoilerModel Number Jacket Depth "A" Rear of Jacket to C/L of Top Flue Outlet "B"
  • p. 22/26
    20 Table 7.1: Boiler Ratings ✸ As an ENERGY STAR ® Partner, PB Heat, LLC has determined that these firing rates meet the ENERGY STAR guidelines for energy efficiency. ✝ Top venting only. ✚ Nozzles for these firing rates not provided as standard equipment.
  • p. 23/26
    21 REPAIR PARTS 8. REPAIR PARTS Repair parts are available from your installer or by contacting PB Heat, LLC,131 S. Church St, Bally, PA 19503. Note: Remember to include boiler model number and serial number when ordering parts. Table 8.1 Item No.* Stock
  • p. 24/26
    22 NOTES
  • p. 25/26
    23 NOTES
  • p. 26/26
    PP8046 R26 (8/08-10M) Printed in U.S.A. ©2008 WBV/WV Boilers Series Oil I n s t a l l a t i o n ,O p e r a t i o n &M a i n t e n a n c eM a n u a l TO T H E I N S TA L L E R : This manual is the property of the owner and must be affixed near the boiler